First-Card Normal Open: During a specified interval, after the first verification by the person having First-Card Normal Open level, the door will be Normal Open, and will automatically restore closing after the valid interval expired.
The user can set First-Card Normal Open for a specific door. The settings include door, door opening time zone and personnel with First-Card Normal Open level. A door can have First-Card Normal Open settings for multiple time zones. The interface of each door will show the number of existing First-Card Normal Open settings. For First-Card Normal Open setting, when adding or editing each record, it is not required to modify the ˇ°current doorˇ±, but to select time zone. When record adding is successful, add personnel that can open the door for a First-Card Normal Open setting record. On the right of the interface, you can browse door opening personnel in a First-Card Normal Open setting and delete current personnel, so that some personnel will not have First-Card Normal Open level any more.
The operation steps are as follows:
1. Click [Set] under ˇ°First-Card Normal Openˇ± of a door to show First-Card Normal Open setting interface;
2. Click [Add], select the time zone of First-Card Normal Open, and click [OK] to save the settings;
3. Click [Add an opening person] under ˇ°Related operationˇ± to set personnel having First-Card Normal Open level.
Click [OK] to save and quit editing.
? Note:
For a door currently in Normal Open time period, consecutive verification of a person having access level for the door for 5 times (the person verification interval should be within 5 second.) can release the current Normal Open status and close the door. The sixth person verification will be a normal verification. This function is only effective at the valid door valid time zone. Normal Open intervals set for other doors within the day and First-Card Normal Open settings will not take effect anymore.